Articles / Energy

Carbon capture eats its own power

20 November 20262 min read

Fit a coal power station with carbon capture and a big slice of the electricity it makes is used to run the capture plant. That power never reaches the grid.

The headline number

With today’s technology, capturing 90% of the CO₂ cuts the power a station sends to the grid by 20 to 30%. Put another way, 75 to 80% of the output typically still reaches the grid.

Worked example, a 1,000 MW coal station with capture:

Share Power
Reaches the grid about 70 to 80% about 700 to 800 MW
Runs the capture plant about 20 to 30% about 200 to 300 MW

The plant’s nameplate stays at 1,000 MW. The grid sees the smaller number.

Where the power goes

1. Steam to clean the solvent (the biggest share). A chemical solvent soaks up the CO₂. Boiling the CO₂ back out takes steam that would otherwise have spun the turbines. This is about two-thirds of the loss. On a 250 MW loss, that is roughly 165 MW of steam-driven output given up.

2. Squeezing the CO₂. Captured CO₂ is compressed to over 100 bar so it can be piped and pushed deep underground. That needs big electric compressors.

3. Fans and pumps. Flue gas has to be pushed through the capture tower, and solvent and cooling water have to circulate, all day, every day.

4. Removing sulphur first. SO₂ ruins the solvent, so the flue gas must be desulphurised before capture. That costs more energy and more water.

How bad it gets depends on the plant

The penalty is not one fixed number. It runs from about 20% where waste heat can be recovered to run the capture plant, to up to 60% extra coal burnt just to run it. The difference is how much of the steam and heat the plant can reuse, and that is a design question for each station.

The engineer’s test

Before capture is used to keep coal running, show the full balance sheet per MWh: energy, water, clean-up, storage site and pipeline.

A capture plant that looks good on tonnes of CO₂ can still look poor per megawatt-hour delivered. The balance sheet should state the net output first.