Articles

Articles from BTF Group.

Practical articles on engineering, automation, software and applied AI for industry. Looking for structured learning? See our courses.

Engineering28 November 2026

Boiler drum level: why swell and shrink fool a single-element controller

When steam demand jumps, a boiler's water level rises even though water is leaving. A single-element controller believes the gauge and closes the feedwater valve at the wrong moment. A three-element controller reads the steam flow and does not. A live animation, a narrated walkthrough and the sums, using one illustrative boiler.

8 min read
Engineering28 November 2026

When the boiler feed pump isn't the problem: what is left at the valve

Five boilers share one feedwater header. When a pump stops, each level controller opens its valve wider, but the valve can only pass what the pressure behind it allows. A live animation, a narrated walkthrough and the sums, using one illustrative plant.

10 min read
Safety24 November 2026

How 44 hours of bypass turns SIL 2 into SIL 1: bypasses and management of change

A safety function with a 5-in-1,000 failure probability loses its SIL 2 after just 43.8 hours of bypass in a year. How bypasses are priced, what compensating measures buy, and why change is the other quiet killer.

3 min read
Safety24 November 2026

SIL 3 plus SIL 3 plus SIL 3 equals SIL 2: why a certified device is not a certified loop

Three SIL 3 devices in a loop give a SIL 2 function. What a SIL certificate on a device does and does not say, and why its assumptions follow the device into your plant.

3 min read
Safety24 November 2026

Why two sensors are not twice as safe: common cause failure and the beta factor

The beta factor caps what redundancy can buy. On the worked example, a 1oo2 pair goes from 815 times safer than one sensor to just 5 times safer as common cause rises from 0 to 20%.

3 min read
Safety24 November 2026

How to make a SIL number look better: credit diagnostics you do not have

The same worked SIL 2 function becomes SIL 1 when one assumption is removed. What diagnostic coverage is, why a valve is where it is hardest to earn, and the exact break-even.

5 min read
Safety24 November 2026

The valve decides: final element SIL, closing time and process safety time

A safety function can have a perfect PFD and still be too slow. The shutdown valve carries 53.9% of the worked example's failure budget, and its closing time leaves only 0.5 seconds of margin against the process safety time.

3 min read
Safety24 November 2026

How a SIL 2 calculation gets vetoed: hardware fault tolerance and safe failure fraction

The arithmetic can say SIL 2 while the architecture says no. Safe failure fraction and hardware fault tolerance, on the worked example, and how removing diagnostics drops a transmitter's SFF from 95.2% to 68.0%.

3 min read
Safety24 November 2026

Same plant, two SILs: low demand, high demand and PFH explained

The same three devices are SIL 2 as a low-demand function and SIL 1 as a high-demand one. Demand mode decides which scale you are measured on, and PFH versus PFDavg explained with the worked example.

3 min read
Safety24 November 2026

The SIL number that hides the worst day: PFD over time and partial stroke testing

PFDavg is an average, and a safety function is not equally safe every day. On the worked example the worst day is 1.97 times the average, and a partial stroke test on the valve cuts the average by up to 35%.

3 min read
Safety24 November 2026

Why your proof test does not find everything: proof test coverage and the SIL you really have

A proof test that finds 90% of the valve's hidden failures sounds excellent. On the worked SIL 2 example it is the difference between 0.0050 and 0.0087, and at 80% the function drops to SIL 1.

3 min read
Safety24 November 2026

The cost of a safe plant: spurious trips and what they really cost

Safety has a price paid in false trips. On the worked example, a 1oo2 sensor pair costs R6,570 more per year in spurious trips than one sensor, while a 2oo3 set saves R6,567. The most dangerous false trip is the one that gets the function bypassed.

2 min read
Safety24 November 2026

How to set a SIL target: start from the explosion, a LOPA worked example

A layer of protection analysis, worked in numbers. How a hazard becomes a required PFD, and how one over-generous protection layer moves the target from SIL 3 to SIL 1.

3 min read
Safety24 November 2026

1oo2 vs 2oo3 voting: how to build a safe system that trips your plant every month

What 1oo1, 1oo2, 2oo2 and 2oo3 voting really buy you, on the worked SIL example. Safety, false trips, and why redundancy only fixes the part you duplicate.

3 min read
Instrumentation24 November 2026

How to buy a control valve that fails: size it for one day only

A control valve sized only for normal flow is a guess. Work backwards from the day it fails, and the three-case sizing method explains itself. Includes an interactive model.

4 min read
Governance23 November 2026

How to wreck a project, and the governance that stops it

Governance is easiest to understand backwards. Start at the wreckage, and every layer of the architecture explains itself.

2 min read
Energy23 November 2026

Headless river turbines: where does the power come from?

A river turbine has no dam, so it has no head. Except it does: the water's own speed is a head. An interactive model shows how much power comes from velocity and how much from a drop, and why even a small step usually wins.

4 min read
Instrumentation23 November 2026

How a Coriolis meter works: it measures lateness, not flow

A Coriolis meter has no flow sensor. It shakes a tube and measures how late one side of it arrives. An interactive model shows the force, the twist, the time lag, and why the same tube also reads density.

4 min read
Energy23 November 2026

Size a home solar system backwards: start from the night

One illustrative South African home, sized in the right order: the evening outage sets the battery, the busiest minute sets the inverter, and only then does the sun set the panels. A live animation and a narrated walkthrough.

7 min read
Energy22 November 2026

How carbon capture works, step by step

Follow the CO₂ through an amine capture plant, from flue gas to a well deep underground. A live animation, and the energy price each step carries.

3 min read
Safety22 November 2026

The mentor's dilemma: survive the system, or change it?

Every project has a Haymitch, the experienced hand who survived the system and now teaches newcomers how to cope with it. Are they teaching survival, or change?

6 min read
Safety22 November 2026

What happens to a SIL rating when a proof test is skipped?

One skipped annual test takes our worked SIL 2 example from 0.0050 to 0.0099, a hair under the limit. Two skipped tests and it is SIL 1. Try it yourself in the simulator.

5 min read
Safety21 November 2026

How a SIL calculation works: ask how it fails

A SIL rating is a probability of failure, not success. One worked example, from the sensor to the verdict, in a 60-second video and a full walkthrough.

4 min read
Energy21 November 2026

South African data centres: how much power and water?

Data centres draw an estimated 2 to 4% of South Africa's electricity today, the announced projects would more than double that, and nobody publishes the water figure.

3 min read
Energy20 November 2026

Carbon capture eats its own power

Fit a coal station with carbon capture and a big slice of its output runs the capture plant instead of reaching the grid. A 1,000 MW station delivers only about 700 to 800 MW.

2 min read
Energy20 November 2026

Carbon capture: four engineering facts

Capturing CO₂ from a coal station is only half the job. Four facts about storage depth, sulphur, energy cost and old mines, plus South Africa's onshore basalt option.

2 min read
Power systems19 November 2026

Airports become grid customers

Electric aircraft need fast turnarounds, and fast turnarounds need megawatt-scale chargers. That turns airports into serious grid customers, with four jobs for power engineers.

3 min read
Engineering practice19 November 2026

As routine calculation becomes a commodity, value moves to judgement

Pioneers explore, settlers productise, town planners industrialise. As AI turns routine calculation into a commodity, the engineering frontier moves left. A Wardley map of an engineering consulting practice.

2 min read
Systems engineering19 November 2026

The V-Model: verify the design, validate the product

The V-Model is as basic to engineering as PMBOK is to project management. Verify the design down the left leg, validate the product up the right, and tie every specification to its test.

2 min read
Power systems19 November 2026

Why underground cable costs more: the physics

Burying a conductor turns a mostly inductive line into a strongly capacitive one. Six first-principles reasons underground transmission costs more, takes longer to deliver and is harder to repair.

4 min read