Capturing CO₂ from a coal station is only half the job. Here is what it takes before, during and after.
1. Storage: CO₂ has to go deep
Below about 800 m, the pressure keeps CO₂ dense, almost like a liquid. Gas that fills 1,000 m³ at the surface shrinks to about 2.7 m³ at 2 km, roughly 370 times smaller. Storage needs porous rock sealed under an impermeable cap rock.
2. Clean-up: SO₂ first
Sulphur poisons the solvent. SO₂ reacts with the amine solvent to form “heat-stable salts” that steam cannot reverse, so the solvent is used up for good. Flue gas must therefore be desulphurised before capture. Most older coal stations do not have this.
3. Energy: capture eats its own power
A station with capture sends 20 to 30% less power to the grid. Most of the loss is steam diverted from the turbines to boil CO₂ out of the solvent. A 1,000 MW station delivers only about 700 to 800 MW. The detail is in the companion article, Carbon capture eats its own power.
4. Old mines: ash is not CO₂
Old mines suit solids, not gas.
- Ash: yes. South African fly ash and coarse ash set like cement and can be pumped into mine voids as paste backfill, with leach testing.
- CO₂: no. Shallow, fractured coal workings cannot seal in a buoyant gas.
South Africa’s storage picture: basalt as an onshore option
Most conventional storage capacity, in deep saline rock, is offshore. But the basalts of Mpumalanga could store CO₂ onshore, close to the coal stations, by turning it into solid carbonate rock. It is promising, but not yet tested at scale. A pilot is under way at Leandra.
Before CCS is used to keep coal running, show the full balance sheet per MWh: energy, water, clean-up, storage site and pipeline.