Articles / Energy

How carbon capture works, step by step

22 November 20263 min read

Carbon capture is not a filter. A filter is something you throw away when it is full. This is a loop: the same liquid soaks up the CO₂, gives it up, and goes straight back to do it again.

Nothing in the loop is magic. There is one liquid that likes CO₂ when it is cool and lets go of it when it is hot. Everything else is plumbing, and heat. The heat is where the cost hides.

Press play, or pick a step.

Watch it run

Dimmed parts are not gone. They are the rest of the plant, still running, so you can see where each step sits in the loop.

The six steps

  1. Flue gas in. The boiler’s exhaust is mostly nitrogen, with the CO₂ mixed in. It has to be cleaned of sulphur first, because SO₂ reacts with the solvent and ruins it for good.
  2. Absorber. Lean solvent, an amine such as MEA, trickles down the tower. The gas rises through it at about 40 °C. The CO₂ dissolves into the liquid, and the clean gas leaves from the top.
  3. Heat exchanger. The CO₂-loaded (rich) solvent is cool, and it is about to be heated. The hot, regenerated (lean) solvent is on its way back and needs cooling. Swapping heat between them saves steam.
  4. Stripper. At about 120 °C the solvent lets go of the CO₂. Concentrated CO₂ leaves the top. The regenerated solvent goes back to the absorber.
  5. The price. The reboiler that supplies that heat runs on steam diverted from the turbines. Steam that heats solvent is steam that is not making electricity.
  6. Compress and bury. The CO₂ is compressed to over 100 bar and injected below about 800 m, where the pressure keeps it dense, under a cap rock that seals it in.

Where the cost shows up

Capturing 90% of the CO₂ cuts the power a station sends to the grid by 20 to 30%. A 1,000 MW station delivers about 700 to 800 MW. Most of that loss sits in step 5. The detail is in Carbon capture eats its own power, and the sulphur and storage facts are in Carbon capture: four engineering facts.

What this animation leaves out

It is a teaching schematic, not a design, and nothing on it is to scale.

  • Real plants add a water wash, solvent filtering and cooling, pumps, and a good deal of control.
  • The temperatures (about 40 °C and about 120 °C) are typical figures for an amine plant, not a specific project’s design.
  • Storage depth is drawn short. Real injection wells run far deeper than the picture suggests.
  • Other solvents and other capture routes exist. This is the common amine, post-combustion case.

The question to ask on any project

Every step above is easy to say and hard to power. When a station tells you it captures 90% of its CO₂, the second number matters as much as the first: how much of its output does it burn to do it?

If a station told you it captures 90% of its CO₂, would you ask how much of its power it uses to do it?