A river turbine has no dam, so where does its power come from? From a drop you cannot see. Moving water carries its own head, called velocity head, and it is V² ÷ 2g. At 2 m/s that is 0.20 m, about the height of a ruler.
Twenty centimetres is not much, which is why river turbines are small machines. Now add a real drop, even half a metre, and the drop usually takes most of the power. Move the sliders and watch it happen.
Watch it run
Pick a preset, then change one slider at a time. The bar under the river shows how the power splits between velocity and drop, and the live working-out underneath updates with every move.
The narrated walkthrough
The full version, about two minutes, narrated with a synthetic voice. It walks through the same worked numbers as the model.
Two formulas, one idea
A dam turbine takes its power from the water falling through a height H:
P_h = ρ · g · Q · H · η
A river turbine in open flow takes it from the water’s speed V through a rotor of area A:
P_k = ½ · ρ · A · V³ · Cp
They look unrelated, and they are the same formula. Put the velocity head into the dam formula: ρ · g · Q · h_v = ρ · g · (A · V) · (V² ÷ 2g) = ½ · ρ · A · V³. The river turbine formula is the dam formula with the water’s own speed standing in for a height.
Two limits matter. The rotor efficiency Cp cannot pass the Betz limit of 0.593 for any rotor in open flow, and in practice it is lower: the model starts at 0.35. And a river turbine turns slowly and at a variable speed, so an inverter converts its output to a steady 50 Hz. The rotor never has to match the grid.
Two worked cases from the model
The defaults are a 2 m/s river, a 1.5 m rotor, Cp 0.35 and 90% generator and inverter efficiency. The rotor sweeps 1.77 m², so the kinetic power is ½ × 1000 × 1.77 × 2³ × 0.35 = 2.47 kW. After the generator and inverter that is 2.23 kW, which the model reads as about 4 homes at an average of 0.5 kW each. The rotor turns at 76 rpm.
Now the preset Weir, 1.5 m drop: 1.5 m/s, a 1.5 m rotor and a 1.5 m drop. Velocity still gives 1.04 kW. The drop gives 31.2 kW, because the same flow now falls through a real height. About 97% of the power comes from the drop. The stepped-channel preset, with only a 0.6 m step, still gets about 89% of its power from the step.
What the dials mean
- River velocity. The speed of the water, in m/s. Power rises with its cube, so doubling the speed gives eight times the kinetic power.
- Velocity head. V² ÷ 2g, in metres: the height the water’s speed is worth.
- Flow through the rotor. Area times speed, in m³/s.
- Rotor speed. In rpm, from a tip-speed ratio of 3.
- Electrical output. What leaves the inverter, in kW.
- Output per m² of rotor. A way to compare rotors of different sizes.
What this model leaves out
It is a simplified teaching model, not a design. It assumes water density of 1,000 kg/m³, g = 9.81 m/s², a rotor tip-speed ratio of 3 and an average household demand of 0.5 kW. The head term assumes the water is channelled through the turbine at a weir or step.
Real sites lose energy to friction, channel blockage and debris. River flow changes with the seasons, so measure the dry-season velocity before sizing anything. And the cube law cuts both ways: a river that runs at half its wet-season speed gives one eighth of the kinetic power. It is the same trap as in Carbon capture eats its own power: the gross number flatters, and the net number is the one that matters.
The question to ask about any river site
The velocity of a river is cheap to measure and easy to be wrong about. A drop, where one exists, is usually worth more than the speed. Before you size a machine, find out which of the two your site really has.
If a site gave you a 1.8 m/s current and a 0.6 m step, which would you measure first, and which would you build around?